Explosion-proof single-turn electric servo drive UP 2-Ex-M

Explosion-proof single-turn electric servo drive UP 2-Ex-M

Type number: 337
Enclosure: IP 66, IP 68
Trip torque: 75 to 300 Nm
Rebuild time: 5 to 80 s/90°
Working angle: 60 to 360 °
Weight: 20 to 24 kg
Ambient temperature: -60 to 55 °C
Connecting flange: F07, F10
Type of protection: II 2G Ex db IIC T5 Gb, II 2G Ex db eb IIC T5 Gb, II 2D Ex tb IIIC T100°C Db

Hi, my name Is Marko. I will be happy to help/advise you

Ing. Marko Čižmárik

Standard equipment

  • Supply voltage 230 V AC
  • Terminal connection
  • 2 torque switches
  • 2 position switches
  • 2 additional position switches
  • Heating resistor with thermal switch
  • Thermal protection of the electric motor
  • Local locator
  • ISO 5211 mechanical connection - flanges F07/F10
  • Mechanical end stops
  • Manual control

Advanced equipment

  • Supply voltage:
    • 24 V, 220 V, 3x380 V, 3x400 V AC / 50 Hz
    • 24 V, 120 V AC / 60 Hz
    • 24 V DC
  • Position transmitter with signal:
    • resistance 1x100 Ω, 1x2000 Ω, 2x100 Ω, 2x2000 Ω
    • current 0/4 to 20 mA from R/I converter (with/without source)
    • current 4 to 20 mA (capacitive transmitter with/without source)

Similar products

500 series shut-off valve

Body construction: Inter-flange - with through holes (WAFER) DN 50 - DN 400 Work pressure: PN 6, PN 10, PN 16 Operating temperature: -40 to 200 °C Marking according to: ČSN EN 19 Connection parameters: ČSN EN 1092-1, ANSI B16.5, DIN 2631 - 35
Body construction: Inter-flange - with through holes (WAFER) DN 50 - DN 400 Work pressure: PN 6, PN 10, PN 16 Operating temperature: -40 to 200 °C

900 series shut-off valve

Body construction: Among the flanged ones - DN 32 – 150, Double flange - DN 50 - 2200 Work pressure: PN 6, PN 10, PN 16 Operating temperature: -40 to 150 °C Marking according to: ČSN EN 19 Connection parameters: ČSN EN 1092-1, ANSI B16.5, Class 150 BS 10 tab D to E
Body construction: Among the flanged ones - DN 32 – 150, Double flange - DN 50 - 2200 Work pressure: PN 6, PN 10, PN 16 Operating temperature: -40 to 150 °C

600 series shut-off valve

Body construction: DN 32, DN 150 Work pressure: PN 6, PN 10, PN 16 Operating temperature: -10 to 125 °C Marking according to: ČSN EN 19 Connection parameters: ČSN EN 1092-1, ANSI B16.5
Body construction: DN 32, DN 150 Work pressure: PN 6, PN 10, PN 16 Operating temperature: -10 to 125 °C

Double-flange shut-off valve series 2E3

Body construction: DN 150, DN 2000 Work pressure: PN 6, PN 10, PN 16, PN 25, PN 40 Operating temperature: -10 to 80 °C Connection parameters: EN 1092/BS4504 (DIN 2501), ASME B16.5 Class 150 Construction length acc: EN 558 -1/14, ISO 5752-14, EN 558 -1/13
Body construction: DN 150, DN 2000 Work pressure: PN 6, PN 10, PN 16, PN 25, PN 40 Operating temperature: -10 to 80 °C

2E series double eccentric shut-off valve

Body construction: DN 50, DN 800 Work pressure: PN 6, PN 10, PN 16, PN 25, PN 40 Operating temperature: -60 to 320 °C Marking according to: ČSN EN 19 Connection parameters: ČSN EN 1092-1, 2, ANSI B16.5 Class 150, BS10 tab. D to E
Body construction: DN 50, DN 800 Work pressure: PN 6, PN 10, PN 16, PN 25, PN 40 Operating temperature: -60 to 320 °C

3E series triple eccentric shut-off valve

Body construction: DN 80, DN 500 Work pressure: PN 25, PN 40, PN 50 Operating temperature: -60 to 500 °C Marking according to: ČSN EN 19 Connection parameters: ČSN EN 1092-1, ANSI B16.5, DIN 2631 - 35
Body construction: DN 80, DN 500 Work pressure: PN 25, PN 40, PN 50 Operating temperature: -60 to 500 °C

Shut-off valves V30 115 540

Light: DN 15, DN 150 Work pressure: PN 40 Operating temperature: -50 to 400 °C Construction length acc: EN 558-1 Materials: Body - Steel 42 2643, Cone - DN 15 – 100 (Stainless steel), DN 125 – 150 (Carbon steel), Saddle - Stainless steel
Light: DN 15, DN 150 Work pressure: PN 40 Operating temperature: -50 to 400 °C

Shut-off valves V30 115 616

Light: DN 15, DN 150 Work pressure: PN 16 Operating temperature: 300 °C Construction length acc: EN 558-1 Materials: Body - Gray cast iron GG25, Cone - Stainless steel, Saddle - Stainless steel
Light: DN 15, DN 150 Work pressure: PN 16 Operating temperature: 300 °C

Three-way flanged ball valve

Body construction: DN 25, DN 150 Work pressure: PN 16 Operating temperature: -20 to 150 °C Tightness: Class A Construction according to: EN 12516
Body construction: DN 25, DN 150 Work pressure: PN 16 Operating temperature: -20 to 150 °C

Inter-flange ball valve

Body construction: DN 15, DN 150 Work pressure: PN 16 Operating temperature: -20 to 180 °C Tightness: Class A Construction according to: EN 12516
Body construction: DN 15, DN 150 Work pressure: PN 16 Operating temperature: -20 to 180 °C

Category products

Explosion-proof single-turn electric servo drive UP 2.4 Ex-M

Type number: 338 Enclosure: IP 66, IP 67 Trip torque: 110 to 800 Nm Rebuild time: 20 to 160 s/90° Working angle: 60 to 360 °
Type number: 338 Enclosure: IP 66, IP 67 Trip torque: 110 to 800 Nm

Explosion-proof electric single-turn servo drive UP 0-Ex-M

Type number: 335 Enclosure: IP 66, IP 68 Trip torque: 7.5 to 63 Nm Rebuild time: 5 to 80 s/90° Working angle: 60 to 360 °
Type number: 335 Enclosure: IP 66, IP 68 Trip torque: 7.5 to 63 Nm

Explosion-proof single-turn electric servo drive UP 1-Ex-M

Type number: 336 Enclosure: IP 66, IP 68 Trip torque: 22 to 100 Nm Rebuild time: 5 to 80 s/90° Working angle: 60 to 360 °
Type number: 336 Enclosure: IP 66, IP 68 Trip torque: 22 to 100 Nm

Explosion-proof single-turn electric servo drive UP 2-Ex-M

Type number: 337 Enclosure: IP 66, IP 68 Trip torque: 75 to 300 Nm Rebuild time: 5 to 80 s/90° Working angle: 60 to 360 °
Type number: 337 Enclosure: IP 66, IP 68 Trip torque: 75 to 300 Nm

Explosion-proof single-turn electric servo drive UP 2.5-Ex-M

Type number: 339 Enclosure: IP 66, IP 68 Trip torque: 250 to 1200 Nm Rebuild time: 20 to 160 s/90° Working angle: 60 to 360 °
Type number: 339 Enclosure: IP 66, IP 68 Trip torque: 250 to 1200 Nm

An important fact of reliable operation is not only the correct design of fittings and servo drives, but also their subsequent care. With regular inspections and planned maintenance, you will prevent malfunctions and thus increase the reliability of the operation and extend its service life. For this purpose, the company REGADA also offers you comprehensive care of servo drives in your operation or just a selection from some of the listed services:

  1. Supervision during the first start-up of actuators in operation
  2. Connection and testing of actuators
  3. Connections and start-up of Rematic actuators - instruction
  4. Attaching the actuators to the valves and starting them
  5. Maintenance of actuators and periodic inspections
  6. Post-warranty repairs at the customer
  7. Post-warranty repair offer in Regada
  8. Training of service personnel
  9. Spare parts