Body construction: DN 50, DN 800
Work pressure: PN 6, PN 10, PN 16, PN 25, PN 40
Operating temperature: -60 to 320 °C
Marking according to: ČSN EN 19
Connection parameters: ČSN EN 1092-1, 2, ANSI B16.5 Class 150, BS10 tab. D to E
Construction length acc: EN 558 row 20 (DIN 3202 T3 K1), ISO 5752 row 20, API 609 tab.1 EN 593
Leakage test: ČSN EN12266-1, Class A, ISO 5208, Class A, API 598
The shape of the sealing surface of the counterflange acc: ČSN EN 1092-1, 2, ANSI RF
Tightness class: A/C

Application: Double-eccentric shut-off valves of the 2E series are industrial fittings designed to completely close or open the medium flow. They can also be used for coarse flow regulation. The dampers are designed and constructed for operation in very demanding industrial conditions, where special emphasis is placed on safety, trouble-free operation and minimal maintenance during operation. Dampers can be used in industrial applications such as nuclear energy, water management, gas distribution, chemical industry, petrochemical plants, metallurgy or heavy industry in general, recuperation and heating systems, paper industry and cellulose processing, shipping industry, hydrocarbon processing or aviation fuel storage. Series 2E dampers are certified for use in explosive environments according to the ATEX standard.

Design: Inter-flange - with through holes (Wafer), with threaded holes (Lug)

More information from the seller

Similar products

Single-turn electric servo drive SP 0-M

Type number: 280 Enclosure: IP 54, IP 67, IP 68 Trip torque: 4 to 40 Nm Rebuild time: 15 to 160 s/90° Working angle: 90 to 270 °
Type number: 280 Enclosure: IP 54, IP 67, IP 68 Trip torque: 4 to 40 Nm

Electric part-turn actuator SP 0

Type number: 280 Industry use: Energy, Water, Industry Enclosure: IP 54, IP 67, IP 68 Trip torque: 4 to 40 Nm Rebuild time: 15 to 160 s/90°
Type number: 280 Industry use: Energy, Water, Industry Enclosure: IP 54, IP 67, IP 68

Single-turn electric servo drive SP 0.1-M

Type number: 331 Enclosure: IP 65, IP 67, IP 68 Trip torque: 16 to 50 Nm Rebuild time: 10 to 160 s/90° Working angle: 60 to 360 °
Type number: 331 Enclosure: IP 65, IP 67, IP 68 Trip torque: 16 to 50 Nm

Non-explosive electric single-turn servo drive SP 2.3-Ex

Type number: 293 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 67 Trip torque: 290 Nm Rebuild time: 20 to 160 s/90°
Type number: 293 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 67

Non-explosive electric single-turn servo drive SP 2.4-Ex

Type number: 294 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 67 Trip torque: 575 Nm Rebuild time: 40 to 160 s/90°
Type number: 294 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 67

Electric part-turn actuator SP 1

Type number: 281 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68 Trip torque: 46 to 100 Nm Rebuild time: 10 to 80 s/90°
Type number: 281 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68

Single-turn electric servo drive SP 1-M

Type number: 281 Enclosure: IP 67, IP 68 Trip torque: 46 to 100 Nm Rebuild time: 10 to 80 s/90° Working angle: 60 to 360 °
Type number: 281 Enclosure: IP 67, IP 68 Trip torque: 46 to 100 Nm

Electric part-turn actuator SP 2

Type number: 282 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68 Trip torque: 72 to 145 Nm Rebuild time: 5 to 80 s/90°
Type number: 282 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68

Electric part-turn actuator SP 2.3

Type number: 283 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68 Trip torque: 290 to 350 Nm Rebuild time: 20 to 160 s/90°
Type number: 283 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68

Single-turn electric servo drive SP 2-M

Type number: 282 Enclosure: IP 67, IP 68 Trip torque: 72 to 175 Nm Rebuild time: 5 to 80 s/90° Working angle: 60 to 360 °
Type number: 282 Enclosure: IP 67, IP 68 Trip torque: 72 to 175 Nm

Category products

3E series triple eccentric shut-off valve

Body construction: DN 80, DN 500 Work pressure: PN 25, PN 40, PN 50 Operating temperature: -60 to 500 °C Marking according to: ČSN EN 19 Connection parameters: ČSN EN 1092-1, ANSI B16.5, DIN 2631 - 35
Body construction: DN 80, DN 500 Work pressure: PN 25, PN 40, PN 50 Operating temperature: -60 to 500 °C

2E series double eccentric shut-off valve

Body construction: DN 50, DN 800 Work pressure: PN 6, PN 10, PN 16, PN 25, PN 40 Operating temperature: -60 to 320 °C Marking according to: ČSN EN 19 Connection parameters: ČSN EN 1092-1, 2, ANSI B16.5 Class 150, BS10 tab. D to E
Body construction: DN 50, DN 800 Work pressure: PN 6, PN 10, PN 16, PN 25, PN 40 Operating temperature: -60 to 320 °C

Double-flange shut-off valve series 2E3

Body construction: DN 150, DN 2000 Work pressure: PN 6, PN 10, PN 16, PN 25, PN 40 Operating temperature: -10 to 80 °C Connection parameters: EN 1092/BS4504 (DIN 2501), ASME B16.5 Class 150 Construction length acc: EN 558 -1/14, ISO 5752-14, EN 558 -1/13
Body construction: DN 150, DN 2000 Work pressure: PN 6, PN 10, PN 16, PN 25, PN 40 Operating temperature: -10 to 80 °C

An important fact of reliable operation is not only the correct design of fittings and servo drives, but also their subsequent care. With regular inspections and planned maintenance, you will prevent malfunctions and thus increase the reliability of the operation and extend its service life. For this purpose, the company REGADA also offers you comprehensive care of servo drives in your operation or just a selection from some of the listed services:

  1. Supervision during the first start-up of actuators in operation
  2. Connection and testing of actuators
  3. Connections and start-up of Rematic actuators - instruction
  4. Attaching the actuators to the valves and starting them
  5. Maintenance of actuators and periodic inspections
  6. Post-warranty repairs at the customer
  7. Post-warranty repair offer in Regada
  8. Training of service personnel
  9. Spare parts