Alphair pneumatic actuator - RE series - with external stops

Alphair pneumatic actuator - RE series - with external stops

Output torque of double-acting drives: 2,3 to 13337 Nm
Output torque of single-acting drives (from air): 2.3 to 10368 Nm
Output torque of single-acting drives (from springs): 3.8 to 5997 Nm
Air pressure: max. 8 (10) Bar
Working angle: 90 °
Power supply: dry or lubricated filtered compressed air
Ambient temperature: -20 to 80 °C
Work position: any

Standard equipment

  • Working angle: 90°
  • Working temperature: -20 to +80°C
  • Surface protection: AV (hard anodizing protection)
  • Mechanical connection: ISO 5211 / DIN 3337
  • Connection of switchboards and accessories according to the NAMUR-VDI/VDE 3845 standard

Advanced equipment

  • Working temperature: -40 to +80°C or -20 to +150°C
  • Location indicator
  • Surface protection: NN (nickel plating with high phosphorus content); TF-TF (anodized + PTFE coating)

Similar products

500 series shut-off valve

Body construction: Inter-flange - with through holes (WAFER) DN 50 - DN 400 Work pressure: PN 6, PN 10, PN 16 Operating temperature: -40 to 200 °C Marking according to: ČSN EN 19 Connection parameters: ČSN EN 1092-1, ANSI B16.5, DIN 2631 - 35
Body construction: Inter-flange - with through holes (WAFER) DN 50 - DN 400 Work pressure: PN 6, PN 10, PN 16 Operating temperature: -40 to 200 °C

900 series shut-off valve

Body construction: Among the flanged ones - DN 32 – 150, Double flange - DN 50 - 2200 Work pressure: PN 6, PN 10, PN 16 Operating temperature: -40 to 150 °C Marking according to: ČSN EN 19 Connection parameters: ČSN EN 1092-1, ANSI B16.5, Class 150 BS 10 tab D to E
Body construction: Among the flanged ones - DN 32 – 150, Double flange - DN 50 - 2200 Work pressure: PN 6, PN 10, PN 16 Operating temperature: -40 to 150 °C

600 series shut-off valve

Body construction: DN 32, DN 150 Work pressure: PN 6, PN 10, PN 16 Operating temperature: -10 to 125 °C Marking according to: ČSN EN 19 Connection parameters: ČSN EN 1092-1, ANSI B16.5
Body construction: DN 32, DN 150 Work pressure: PN 6, PN 10, PN 16 Operating temperature: -10 to 125 °C

Double-flange shut-off valve series 2E3

Body construction: DN 150, DN 2000 Work pressure: PN 6, PN 10, PN 16, PN 25, PN 40 Operating temperature: -10 to 80 °C Connection parameters: EN 1092/BS4504 (DIN 2501), ASME B16.5 Class 150 Construction length acc: EN 558 -1/14, ISO 5752-14, EN 558 -1/13
Body construction: DN 150, DN 2000 Work pressure: PN 6, PN 10, PN 16, PN 25, PN 40 Operating temperature: -10 to 80 °C

2E series double eccentric shut-off valve

Body construction: DN 50, DN 800 Work pressure: PN 6, PN 10, PN 16, PN 25, PN 40 Operating temperature: -60 to 320 °C Marking according to: ČSN EN 19 Connection parameters: ČSN EN 1092-1, 2, ANSI B16.5 Class 150, BS10 tab. D to E
Body construction: DN 50, DN 800 Work pressure: PN 6, PN 10, PN 16, PN 25, PN 40 Operating temperature: -60 to 320 °C

3E series triple eccentric shut-off valve

Body construction: DN 80, DN 500 Work pressure: PN 25, PN 40, PN 50 Operating temperature: -60 to 500 °C Marking according to: ČSN EN 19 Connection parameters: ČSN EN 1092-1, ANSI B16.5, DIN 2631 - 35
Body construction: DN 80, DN 500 Work pressure: PN 25, PN 40, PN 50 Operating temperature: -60 to 500 °C

Three-way flanged ball valve

Body construction: DN 25, DN 150 Work pressure: PN 16 Operating temperature: -20 to 150 °C Tightness: Class A Construction according to: EN 12516
Body construction: DN 25, DN 150 Work pressure: PN 16 Operating temperature: -20 to 150 °C

Inter-flange ball valve

Body construction: DN 15, DN 150 Work pressure: PN 16 Operating temperature: -20 to 180 °C Tightness: Class A Construction according to: EN 12516
Body construction: DN 15, DN 150 Work pressure: PN 16 Operating temperature: -20 to 180 °C

Two-piece flanged ball valve II

Body construction: DN 15, DN 300 Work pressure: PN 16/40 Operating temperature: -20 to 200 °C Tightness: Class A Construction according to: EN 12516-1
Body construction: DN 15, DN 300 Work pressure: PN 16/40 Operating temperature: -20 to 200 °C

Two-piece flanged ball valve I

Body construction: DN 15, DN 300 Work pressure: PN 40 Operating temperature: -20 to 230 °C Tightness: Class A Construction according to: IN 1983, ISO 17292
Body construction: DN 15, DN 300 Work pressure: PN 40 Operating temperature: -20 to 230 °C

Category products

Alphair pneumatic actuator - AP series - with internal stops

Output torque of double-acting drives: 3 to 13367 Nm Output torque of single-acting drives (from air): 2 to 10 368 Nm Output torque of single-acting drives (from springs): 3.5 to 5998 Nm Air pressure: min. 1 to max. 8 Bar Working angle: 90 °
Output torque of double-acting drives: 3 to 13367 Nm Output torque of single-acting drives (from air): 2 to 10 368 Nm Output torque of single-acting drives (from springs): 3.5 to 5998 Nm

Alphair pneumatic actuator - RE series - with external stops

Output torque of double-acting drives: 2,3 to 13337 Nm Output torque of single-acting drives (from air): 2.3 to 10368 Nm Output torque of single-acting drives (from springs): 3.8 to 5997 Nm Air pressure: max. 8 (10) Bar Working angle: 90 °
Output torque of double-acting drives: 2,3 to 13337 Nm Output torque of single-acting drives (from air): 2.3 to 10368 Nm Output torque of single-acting drives (from springs): 3.8 to 5997 Nm

An important fact of reliable operation is not only the correct design of fittings and servo drives, but also their subsequent care. With regular inspections and planned maintenance, you will prevent malfunctions and thus increase the reliability of the operation and extend its service life. For this purpose, the company REGADA also offers you comprehensive care of servo drives in your operation or just a selection from some of the listed services:

  1. Supervision during the first start-up of actuators in operation
  2. Connection and testing of actuators
  3. Connections and start-up of Rematic actuators - instruction
  4. Attaching the actuators to the valves and starting them
  5. Maintenance of actuators and periodic inspections
  6. Post-warranty repairs at the customer
  7. Post-warranty repair offer in Regada
  8. Training of service personnel
  9. Spare parts