Two-way regulating valves RV 113 R and three-way RV 113 M

Two-way regulating valves RV 113 R and three-way RV 113 M

Light: DN 15, DN 150
Work pressure: PN 6, PN 16, PN 25
Operating temperature: 0 to 150 °C
Connection parameters: ČSN-EN 1092-1 (flange type B1)
Construction length acc: row 1 according to ČSN-EN 558-1 + A1
Materials: Body - gray cast iron EN-JL 1040, or ductile iron EN-JS 1025, Cone - corrosion-resistant steel 1.4027, Seal in the saddle, or stuffing box seal – EPDM
Leakage test: class IV according to ČSN-EN 1349

Two-way regulating valves RV 113 R and three-way regulating valves RV 113M are intended for use in heating and air conditioning technology. Valves RV 113 are also produced in a silicone-free version. These valves are suitable for applications where there must be no penetration of substances that reduce the quality of paints (e.g. automotive industry). Valves of the RV 113 series are suitable for use in devices where the regulated medium is water, air and other media compatible with the material of the body and internal parts of the fitting in the temperature range from 2˚C to 150˚C. The sealing surfaces of the throttling system are resistant to common sludge and impurities of the medium, however, in the presence of abrasive impurities, it is necessary to place a filter in the pipeline before the valve to ensure long-term reliable function and tightness. Valves must not operate in conditions where there is a risk of cavitation. They are not suitable for steam or steam condensate.

MORE ABOUT RV 113 R
MORE ABOUT RV 113 M


Similar products

Explosive electric linear actuator ST 1-Ex

Type number: 411 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 67 Cut-off thrust: 2300 to 10000 N Operating speed: 8 to 80 mm/min
Type number: 411 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 67

Non-explosive electric linear actuator UL 0-Ex

Type number: 535 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 68 Cut-off thrust: 1400 to 6900 N Operating speed: 10 to 80 mm/min
Type number: 535 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 68

Non-explosive electric linear actuator UL 1-Ex

Type number: 536 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 68 Cut-off thrust: 1400 to 12500 N Operating speed: 10 to 80 mm/min
Type number: 536 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 68

Non-explosive electric linear actuator UL 2-Ex

Type number: 537 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 68 Cut-off thrust: 7000 to 25000 N Operating speed: 14 to 120 mm/min
Type number: 537 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 68

Electric linear actuator ST MINI

Type number: 472 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68 Cut-off thrust: 250 to 1100 N Operating speed: 5 to 40 mm/min
Type number: 472 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68

Non-explosive electric linear actuator MT 3-Ex

Type number: 500 Industry use: Oil and gas, Prach Enclosure: IP 66 Cut-off thrust: 4800 to 36000 N Operating speed: 32 to 180 mm/min
Type number: 500 Industry use: Oil and gas, Prach Enclosure: IP 66

Electric linear actuator ST 0

Type number: 490 Industry use: Energy, Water, Industry Enclosure: IP 54, IP 67, IP 68 Cut-off thrust: 360 to 4500 N Operating speed: 5 to 40 mm/min
Type number: 490 Industry use: Energy, Water, Industry Enclosure: IP 54, IP 67, IP 68

Electric linear actuator ST 0.1

Type number: 498 Industry use: Energy, Water, Industry Enclosure: IP 65, IP 67, IP 68 Cut-off thrust: 1900 to 7200 N Operating speed: 10 to 63 mm/min
Type number: 498 Industry use: Energy, Water, Industry Enclosure: IP 65, IP 67, IP 68

Electric linear actuator ST 1

Type number: 491 Industry use: Energy, Water, Industry Enclosure: IP 65, IP 67, IP 68 Cut-off thrust: 2300 to 10000 N Operating speed: 8 to 80 mm/min
Type number: 491 Industry use: Energy, Water, Industry Enclosure: IP 65, IP 67, IP 68

Electric linear actuator UL 0

Type number: 540 Industry use: Energy, Water, Industry Enclosure: IP 66, IP 68 Cut-off thrust: 1400 to 6900 N Operating speed: 10 to 80 mm/min
Type number: 540 Industry use: Energy, Water, Industry Enclosure: IP 66, IP 68

Category products

Two-way regulating valves RV 102 and three-way RV 103

Light: DN 15, DN 50 Work pressure: PN 16 Operating temperature: 150 °C Connection parameters: ČSN-EN ISO 228-1 resp. ČSN-EN 1092-1 Construction length acc: series M4 according to DIN 3202, series 1 according to ČSN-EN 558-1
Light: DN 15, DN 50 Work pressure: PN 16 Operating temperature: 150 °C

Two-way regulating valves RV 113 R and three-way RV 113 M

Light: DN 15, DN 150 Work pressure: PN 6, PN 16, PN 25 Operating temperature: 150 °C Connection parameters: ČSN-EN 1092-1 (flange type B1) Construction length acc: row 1 according to ČSN-EN 558-1 + A1
Light: DN 15, DN 150 Work pressure: PN 6, PN 16, PN 25 Operating temperature: 150 °C

Two-way regulating and shut-off valves 210, 220, 230 E (Ex)

Light: DN 15, DN 400 Work pressure: PN 6, PN 16, PN 25, PN 40 Operating temperature: -10 to 150 °C Connection parameters: ČSN-EN 1092-1 (flange type B1) Construction length acc: row 1 according to ČSN-EN 558-1
Light: DN 15, DN 400 Work pressure: PN 6, PN 16, PN 25, PN 40 Operating temperature: -10 to 150 °C

Three-way regulating and closing valves 214, 224, 234 E (Ex)

Light: DN 15, DN 400 Work pressure: PN 6, PN 16, PN 25, PN 40 Operating temperature: -10 to 300 °C Connection parameters: ČSN-EN 1092-1/2 (flange type B1) Construction length acc: row 1 according to ČSN-EN 558
Light: DN 15, DN 400 Work pressure: PN 6, PN 16, PN 25, PN 40 Operating temperature: -10 to 300 °C

An important fact of reliable operation is not only the correct design of fittings and servo drives, but also their subsequent care. With regular inspections and planned maintenance, you will prevent malfunctions and thus increase the reliability of the operation and extend its service life. For this purpose, the company REGADA also offers you comprehensive care of servo drives in your operation or just a selection from some of the listed services:

  1. Supervision during the first start-up of actuators in operation
  2. Connection and testing of actuators
  3. Connections and start-up of Rematic actuators - instruction
  4. Attaching the actuators to the valves and starting them
  5. Maintenance of actuators and periodic inspections
  6. Post-warranty repairs at the customer
  7. Post-warranty repair offer in Regada
  8. Training of service personnel
  9. Spare parts