Electric part-turn actuator SP 0

Electric part-turn actuator SP 0

Type number: 280
Industry use: Energy, Water, Industry
Enclosure: IP 54, IP 67, IP 68
Trip torque: 4 to 40 Nm
Rebuild time: 15 to 160 s/90°
Working angle: 90 to 270 °
Weight: 1.4 to 2.5 kg
Ambient temperature: -25 to 55 °C
Connecting flange: F03, F04, F05, F07
Work position: any

Hi, my name Is Marko. I will be happy to help/advise you

Ing. Marko Čižmárik

Standard equipment:

  • Supply voltage 230 V AC
  • Terminal board connection
  • 2 position switches
  • Mechanical flange connection according to ISO 5211, flange size F03, F04
  • Mechanical end stops
  • Enclosure rating IP 54

Advanced equipment:

  • Supply voltage 220 V AC, 24 V AC, 24 V DC
  • 2 additional position switches
  • Position transmitter:
    • single potentiometer 1x100 Ω, 1x2000 Ω
    • electronic position transmitter passive/active, 2-wire/3-wire, 0/4 to 20 mA from R/I converter without source
  • Space heater
  • Mechanical connection according to ISO 5211, flange size F05, F07 - using a bracket
  • Manual control
  • Disengagement of transmission without manual control (for lever version)
  • Mechanical connection with stand, lever and pulls
  • Without end stops
  • Gold coated contacts of microswitches
  • Enclosure rating IP 68

Similar products

500 series shut-off valve

Body construction: Inter-flange - with through holes (WAFER) DN 50 - DN 400 Work pressure: PN 6, PN 10, PN 16 Operating temperature: -40 to 200 °C Marking according to: ČSN EN 19 Connection parameters: ČSN EN 1092-1, ANSI B16.5, DIN 2631 - 35
Body construction: Inter-flange - with through holes (WAFER) DN 50 - DN 400 Work pressure: PN 6, PN 10, PN 16 Operating temperature: -40 to 200 °C

900 series shut-off valve

Body construction: Among the flanged ones - DN 32 – 150, Double flange - DN 50 - 2200 Work pressure: PN 6, PN 10, PN 16 Operating temperature: -40 to 150 °C Marking according to: ČSN EN 19 Connection parameters: ČSN EN 1092-1, ANSI B16.5, Class 150 BS 10 tab D to E
Body construction: Among the flanged ones - DN 32 – 150, Double flange - DN 50 - 2200 Work pressure: PN 6, PN 10, PN 16 Operating temperature: -40 to 150 °C

600 series shut-off valve

Body construction: DN 32, DN 150 Work pressure: PN 6, PN 10, PN 16 Operating temperature: -10 to 125 °C Marking according to: ČSN EN 19 Connection parameters: ČSN EN 1092-1, ANSI B16.5
Body construction: DN 32, DN 150 Work pressure: PN 6, PN 10, PN 16 Operating temperature: -10 to 125 °C

Double-flange shut-off valve series 2E3

Body construction: DN 150, DN 2000 Work pressure: PN 6, PN 10, PN 16, PN 25, PN 40 Operating temperature: -10 to 80 °C Connection parameters: EN 1092/BS4504 (DIN 2501), ASME B16.5 Class 150 Construction length acc: EN 558 -1/14, ISO 5752-14, EN 558 -1/13
Body construction: DN 150, DN 2000 Work pressure: PN 6, PN 10, PN 16, PN 25, PN 40 Operating temperature: -10 to 80 °C

2E series double eccentric shut-off valve

Body construction: DN 50, DN 800 Work pressure: PN 6, PN 10, PN 16, PN 25, PN 40 Operating temperature: -60 to 320 °C Marking according to: ČSN EN 19 Connection parameters: ČSN EN 1092-1, 2, ANSI B16.5 Class 150, BS10 tab. D to E
Body construction: DN 50, DN 800 Work pressure: PN 6, PN 10, PN 16, PN 25, PN 40 Operating temperature: -60 to 320 °C

3E series triple eccentric shut-off valve

Body construction: DN 80, DN 500 Work pressure: PN 25, PN 40, PN 50 Operating temperature: -60 to 500 °C Marking according to: ČSN EN 19 Connection parameters: ČSN EN 1092-1, ANSI B16.5, DIN 2631 - 35
Body construction: DN 80, DN 500 Work pressure: PN 25, PN 40, PN 50 Operating temperature: -60 to 500 °C

Three-way flanged ball valve

Body construction: DN 25, DN 150 Work pressure: PN 16 Operating temperature: -20 to 150 °C Tightness: Class A Construction according to: EN 12516
Body construction: DN 25, DN 150 Work pressure: PN 16 Operating temperature: -20 to 150 °C

Inter-flange ball valve

Body construction: DN 15, DN 150 Work pressure: PN 16 Operating temperature: -20 to 180 °C Tightness: Class A Construction according to: EN 12516
Body construction: DN 15, DN 150 Work pressure: PN 16 Operating temperature: -20 to 180 °C

Two-piece flanged ball valve II

Body construction: DN 15, DN 300 Work pressure: PN 16/40 Operating temperature: -20 to 200 °C Tightness: Class A Construction according to: EN 12516-1
Body construction: DN 15, DN 300 Work pressure: PN 16/40 Operating temperature: -20 to 200 °C

Two-piece flanged ball valve I

Body construction: DN 15, DN 300 Work pressure: PN 40 Operating temperature: -20 to 230 °C Tightness: Class A Construction according to: IN 1983, ISO 17292
Body construction: DN 15, DN 300 Work pressure: PN 40 Operating temperature: -20 to 230 °C

Category products

Electric part-turn actuator SP MIKRO

Type number: 260 Industry use: Energy, Water, Industry Enclosure: IP 65 Trip torque: 8 Nm Rebuild time: 120 s/90°
Type number: 260 Industry use: Energy, Water, Industry Enclosure: IP 65

Electric part-turn actuator SP 0

Type number: 280 Industry use: Energy, Water, Industry Enclosure: IP 54, IP 67, IP 68 Trip torque: 4 to 40 Nm Rebuild time: 15 to 160 s/90°
Type number: 280 Industry use: Energy, Water, Industry Enclosure: IP 54, IP 67, IP 68

Electric part-turn actuator SP 0.1

Type number: 331 Industry use: Energy, Water, Industry Enclosure: IP 65, IP 67, IP 68 Trip torque: 16 to 50 Nm Rebuild time: 10 to 120 s/90°
Type number: 331 Industry use: Energy, Water, Industry Enclosure: IP 65, IP 67, IP 68

Electric part-turn actuator SP 1

Type number: 281 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68 Trip torque: 46 to 100 Nm Rebuild time: 10 to 80 s/90°
Type number: 281 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68

Electric part-turn actuator SP 2

Type number: 282 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68 Trip torque: 72 to 145 Nm Rebuild time: 5 to 80 s/90°
Type number: 282 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68

Electric part-turn actuator SP 2.3

Type number: 283 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68 Trip torque: 290 to 350 Nm Rebuild time: 20 to 160 s/90°
Type number: 283 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68

Electric part-turn actuator SP 2.4

Type number: 284 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68 Trip torque: 575 to 650 Nm Rebuild time: 40 to 160 s/90°
Type number: 284 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68

Electric part-turn actuator UP 1

Type number: 341 Industry use: Energy, Water, Industry Enclosure: IP 66, IP 68 Trip torque: 22 to 170 Nm Rebuild time: 5 to 80 s/90°
Type number: 341 Industry use: Energy, Water, Industry Enclosure: IP 66, IP 68

Electric part-turn actuator UP 2

Type number: 342 Industry use: Energy, Water, Industry Enclosure: IP 66, IP 68 Trip torque: 75 to 300 Nm Rebuild time: 5 to 80 s/90°
Type number: 342 Industry use: Energy, Water, Industry Enclosure: IP 66, IP 68

Electric part-turn actuator UP 2.4

Type number: 343 Industry use: Energy, Water, Industry Enclosure: IP 66, IP 68 Trip torque: 110 to 800 Nm Rebuild time: 20 to 160 s/90°
Type number: 343 Industry use: Energy, Water, Industry Enclosure: IP 66, IP 68

Electric part-turn actuator UP 2.5

Type number: 344 Industry use: Energy, Water, Industry Enclosure: IP 66, IP 68 Trip torque: 300 to 1800 Nm Rebuild time: 20 to 160 s/90°
Type number: 344 Industry use: Energy, Water, Industry Enclosure: IP 66, IP 68

Electric part-turn actuator MPR

Type number: 52 220 Industry use: Energy, Water, Industry Enclosure: IP 67 Trip torque: 25 to 125 Nm Rebuild time: 8 to 34 s/90°
Type number: 52 220 Industry use: Energy, Water, Industry Enclosure: IP 67

An important fact of reliable operation is not only the correct design of fittings and servo drives, but also their subsequent care. With regular inspections and planned maintenance, you will prevent malfunctions and thus increase the reliability of the operation and extend its service life. For this purpose, the company REGADA also offers you comprehensive care of servo drives in your operation or just a selection from some of the listed services:

  1. Supervision during the first start-up of actuators in operation
  2. Connection and testing of actuators
  3. Connections and start-up of Rematic actuators - instruction
  4. Attaching the actuators to the valves and starting them
  5. Maintenance of actuators and periodic inspections
  6. Post-warranty repairs at the customer
  7. Post-warranty repair offer in Regada
  8. Training of service personnel
  9. Spare parts