Non-explosive electric single-turn servo drive UP 2.4-Ex

Non-explosive electric single-turn servo drive UP 2.4-Ex

Type number: 338
Industry use: Oil and gas, Prach
Enclosure: IP 66, IP 68
Trip torque: 110 to 800 Nm
Rebuild time: 20 to 160 s/90°
Working angle: 60 to 360 °
Weight: 29 to 33 kg
Ambient temperature: -60 to 55 °C
Connecting flange: F10, F12
Work position: any
Type of protection: II 2G Ex db IIC T5 Gb, II 2G Ex db eb IIC T5 Gb, II 2D Ex tb IIIC T100°C Db

Hi, my name Is Marko. I will be happy to help/advise you

Ing. Marko Čižmárik

Standard equipment

  • Supply voltage 230 V AC
  • Terminal connection
  • 2 torque switches
  • 2 position switches
  • 2 additional position switches
  • Heating resistor with thermal switch
  • Thermal protection of the electric motor
  • Local locator
  • Mechanical connection ISO 5211
  • Manual control
  • Degree of protection IP 66 / IP 68

Advanced equipment

  • Supply voltage:
    • 24 V AC, 220 V AC, 3x380 V AC, 3x400 V AC / 50Hz
    • 24 V AC, 120 V AC / 60 Hz
    • 24 V DC
  • Position transmitter with signal:
    • resistance 1x100 Ω, 1x2000 Ω, 2x100 Ω, 2x2000 Ω
    • current 0/4 to 20 mA from R/I converter (with/without source)
    • current 4 to 20 mA (capacitive transmitter with/without source)

Similar products

Category products

Non-explosive electric single-turn servo drive SP 1-Ex

Type number: 291 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 67 Trip torque: 46 to 90 Nm Rebuild time: 10 to 80 s/90°
Type number: 291 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 67

Explosion-proof single-turn electric servo drive SP 2-Ex

Type number: 292 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 67 Trip torque: 63 to 145 Nm Rebuild time: 5 to 80 s/90°
Type number: 292 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 67

Non-explosive electric single-turn servo drive SP 2.3-Ex

Type number: 293 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 67 Trip torque: 290 Nm Rebuild time: 20 to 160 s/90°
Type number: 293 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 67

Non-explosive electric single-turn servo drive SP 2.4-Ex

Type number: 294 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 67 Trip torque: 575 Nm Rebuild time: 40 to 160 s/90°
Type number: 294 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 67

Non-explosive electric single-turn servo drive UP 0-Ex

Type number: 335 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 68 Trip torque: 7.5 to 63 Nm Rebuild time: 5 to 80 s/90°
Type number: 335 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 68

Non-explosive electric single-turn servo drive UP 1-Ex

Type number: 336 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 68 Trip torque: 22 to 100 Nm Rebuild time: 5 to 80 s/90°
Type number: 336 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 68

Non-explosive electric single-turn servo drive UP 2-Ex

Type number: 337 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 68 Trip torque: 75 to 300 Nm Rebuild time: 5 to 80 s/90°
Type number: 337 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 68

Non-explosive electric single-turn servo drive UP 2.4-Ex

Type number: 338 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 68 Trip torque: 110 to 800 Nm Rebuild time: 20 to 160 s/90°
Type number: 338 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 68

Non-explosive electric single-turn servo drive UP 2.5-Ex

Type number: 339 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 68 Trip torque: 250 to 1200 Nm Rebuild time: 20 to 160 s/90°
Type number: 339 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 68

An important fact of reliable operation is not only the correct design of fittings and servo drives, but also their subsequent care. With regular inspections and planned maintenance, you will prevent malfunctions and thus increase the reliability of the operation and extend its service life. For this purpose, the company REGADA also offers you comprehensive care of servo drives in your operation or just a selection from some of the listed services:

  1. Supervision during the first start-up of actuators in operation
  2. Connection and testing of actuators
  3. Connections and start-up of Rematic actuators - instruction
  4. Attaching the actuators to the valves and starting them
  5. Maintenance of actuators and periodic inspections
  6. Post-warranty repairs at the customer
  7. Post-warranty repair offer in Regada
  8. Training of service personnel
  9. Spare parts