Explosive environment (ATEX)

Explosion-proof electrical servo drives Standard Ex and Rematic Ex are, according to Directive 94/9EC, equipment designed for use in an environment with a risk of explosion. Servo drives are designed as group II, category 2G or 2D devices. They can work in operations designated as zone 1, 21 and 2, 22.
filter-icon

Products filter

Trip torque

X

Enclosure

X

Connecting flange

X
Showing 13 - 24 from 25 products

Electric multi-turn servo drive UMR 2PA-Ex-M

Type number: 147 Enclosure: IP 66, IP 68 Trip torque: 30 to 100 Nm Rebuild speed: 10 to 40 min−1 Scope of work. of revolutions: 2 to 160
Type number: 147 Enclosure: IP 66, IP 68 Trip torque: 30 to 100 Nm

Non-explosive multi-turn electric servo drive MO 3-Ex-M

Type number: 100 Enclosure: IP 66 Trip torque: 26 to 150 Nm Rebuild speed: 16 to 95 min−1 Scope of work. of revolutions: 1 to 685
Type number: 100 Enclosure: IP 66 Trip torque: 26 to 150 Nm

Multi-turn electric servo drive MOR 3PA-Ex-M

Type number: 109 Enclosure: IP 66 Trip torque: 40 to 150 Nm Rebuild speed: 16 to 95 min−1 Scope of work. of revolutions: 1 to 1000
Type number: 109 Enclosure: IP 66 Trip torque: 40 to 150 Nm

Non-explosive multi-turn electric servo drive MO 4-Ex-M

Type number: 165 Enclosure: IP 66, IP 55 Trip torque: 95 to 500 Nm Rebuild speed: 16 to 180 min−1 Scope of work. of revolutions: 1.75 to 685
Type number: 165 Enclosure: IP 66, IP 55 Trip torque: 95 to 500 Nm

Non-explosive multi-turn electric servo drive MO 5-Ex-M

Type number: 167 Enclosure: IP 66 Trip torque: 300 to 1000 Nm Rebuild speed: 15 to 100 min−1 Scope of work. of revolutions: 1.25 to 500
Type number: 167 Enclosure: IP 66 Trip torque: 300 to 1000 Nm

Multi-turn electric servo drive MOR 5PA-Ex-M

Type number: 168 Enclosure: IP 66 Trip torque: 500 to 1000 Nm Rebuild speed: 15 to 100 min−1 Scope of work. of revolutions: 1 to 800
Type number: 168 Enclosure: IP 66 Trip torque: 500 to 1000 Nm

Non-explosive electrical linear actuator UL 0-Ex-M

Type number: 535 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 68 Cut-off thrust: 1400 to 6900 N Operating speed: 10 to 80 mm/min
Type number: 535 Industry use: Oil and gas, Prach Enclosure: IP 66, IP 68

Non-explosive electric linear actuator UL 1-Ex-M

Type number: 536 Enclosure: IP 66, IP 68 Cut-off thrust: 1400 to 12500 N Operating speed: 10 to 80 mm/min Working stroke: 10 to 80 mm
Type number: 536 Enclosure: IP 66, IP 68 Cut-off thrust: 1400 to 12500 N

Explosion-proof electric linear actuator ULR 1PA-Ex-M

Type number: 546 Enclosure: IP 66, IP 68 Cut-off thrust: 2100 to 12500 N Operating speed: 10 to 80 mm/min Working stroke: 10 to 80 mm
Type number: 546 Enclosure: IP 66, IP 68 Cut-off thrust: 2100 to 12500 N

Non-explosive electric linear actuator UL 2-Ex-M

Type number: 537 Enclosure: IP 66, IP 68 Cut-off thrust: 7000 to 25000 N Operating speed: 14 to 120 mm/min Working stroke: 10 to 120 mm
Type number: 537 Enclosure: IP 66, IP 68 Cut-off thrust: 7000 to 25000 N

Explosion-proof electric linear actuator ULR 2PA-Ex-M

Type number: 547 Enclosure: IP 66, IP 68 Cut-off thrust: 12000 to 25000 N Operating speed: 14 to 120 mm/min Working stroke: 10 to 100 mm
Type number: 547 Enclosure: IP 66, IP 68 Cut-off thrust: 12000 to 25000 N

Explosion-proof electric linear actuator MT 3-Ex-M

Type number: 500 Enclosure: IP 66 Cut-off thrust: 4800 to 36000 N Operating speed: 32 to 180 mm/min Working stroke: 10 to 100 mm
Type number: 500 Enclosure: IP 66 Cut-off thrust: 4800 to 36000 N