Electric part-turn actuator SPR 0PA

Electric part-turn actuator SPR 0PA

Type number: 230
Industry use: Energy, Water, Industry
Enclosure: IP 67, IP 68
Trip torque: 10 to 40 Nm
Rebuild time: 15 to 130 s/90°
Working angle: 60 to 360 °
Weight: 1.4 to 2.4 kg
Ambient temperature: -25 to 55 °C
Connecting flange: F03, F04, F05, F07
Work position: any

Hi, my name Is Marko. I will be happy to help/advise you

Ing. Marko Čižmárik

Standard equipment and functions with DMS3 control unit

  • Supply voltage:
    • 230 V / 50 Hz
  • Terminal board connection
  • Switching off in limit positions
  • 2 freely programmable relays R1, R2 (18 functions)
  • Relay READY
  • Control by unified 0/4 - 20 mA, 4 - 12 mA, 12 - 20 mA, or 0/2 - 10 V (not for DMS3 in 2P version)
  • Control by permanent voltage (+24 V DC) - OPEN, CLOSE
  • Impulse control (inching duty) (+24 V DC) - OPEN, STOP, CLOSE
  • Timing mode / regime of operation
  • ESD (failure reaction) safety function
  • Electronic position transmitter 4 to 20 mA passive (not for DMS3 in 2P version)
  • Output of failure messages
  • Space heater operated by control unit
  • Communication interface RS 232
  • Program for parameters setting by PC
  • Mechanical connection ISO 5211 - flange size F03, F04
  • Manual control
  • Mechanical end stops
  • Enclosure protection IP 67

Additional equipment

  • Supply voltage:
    • 220 V, 24 V / 50 Hz
    • 240 V, 120 V, 110 V, 24 V / 60 Hz
  • Communication cable DB-9F/RJ45
  • Service handle
  • Without mechanical stop ends
  • Version with stand, lever and pulls
  • Mechanical connection ISO 5211 - flange size F05
  • Mechanical connection ISO 5211 - flange size F05
  • Enclosure protection IP 68

Similar products

Category products

Electric part-turn actuator SPR 0PA

Type number: 230 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68 Trip torque: 10 to 40 Nm Rebuild time: 15 to 130 s/90°
Type number: 230 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68

Electric part-turn actuator SPR 0.1PA

Type number: 238 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68 Trip torque: 13 to 50 Nm Rebuild time: 10 to 160 s/90°
Type number: 238 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68

Electric part-turn actuator UPR 1PA

Type number: 381 Industry use: Energy, Water, Industry Enclosure: IP 66, IP 68 Trip torque: 45 to 170 Nm Rebuild time: 5 to 80 s/90°
Type number: 381 Industry use: Energy, Water, Industry Enclosure: IP 66, IP 68

Electric part-turn actuator UPR 2PA

Type number: 382 Industry use: Energy, Water, Industry Enclosure: IP 66, IP 68 Trip torque: 120 to 300 Nm Rebuild time: 5 to 80 s/90°
Type number: 382 Industry use: Energy, Water, Industry Enclosure: IP 66, IP 68

Electric part-turn actuator UPR 2.4PA

Type number: 383 Industry use: Energy, Water, Industry Enclosure: IP 66, IP 68 Trip torque: 180 to 800 Nm Rebuild time: 20 to 160 s/90°
Type number: 383 Industry use: Energy, Water, Industry Enclosure: IP 66, IP 68

Electric part-turn actuator UPR 2.5PA

Type number: 384 Industry use: Energy, Water, Industry Enclosure: IP 66, IP 68 Trip torque: 500 to 1200 Nm Rebuild time: 20 to 160 s/90°
Type number: 384 Industry use: Energy, Water, Industry Enclosure: IP 66, IP 68

Electric part-turn actuator SPR 1PA

Type number: 231 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68 Trip torque: 46 to 90 Nm Rebuild time: 10 to 80 s/90°
Type number: 231 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68

Electric part-turn actuator SPR 2PA

Type number: 232 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68 Trip torque: 72 to 145 Nm Rebuild time: 5 to 80 s/90°
Type number: 232 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68

Single-turn electric servo drive SPR 2.3PA

Type number: 233 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68 Trip torque: 290 Nm Rebuild time: 20 to 160 s/90°
Type number: 233 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68

Electric part-turn actuator SPR 2.4PA

Type number: 234 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68 Trip torque: 575 Nm Rebuild time: 40 to 160 s/90°
Type number: 234 Industry use: Energy, Water, Industry Enclosure: IP 67, IP 68

An important fact of reliable operation is not only the correct design of fittings and servo drives, but also their subsequent care. With regular inspections and planned maintenance, you will prevent malfunctions and thus increase the reliability of the operation and extend its service life. For this purpose, the company REGADA also offers you comprehensive care of servo drives in your operation or just a selection from some of the listed services:

  1. Supervision during the first start-up of actuators in operation
  2. Connection and testing of actuators
  3. Connections and start-up of Rematic actuators - instruction
  4. Attaching the actuators to the valves and starting them
  5. Maintenance of actuators and periodic inspections
  6. Post-warranty repairs at the customer
  7. Post-warranty repair offer in Regada
  8. Training of service personnel
  9. Spare parts
download-icon Download files