Explosion-proof electric multi-turn actuator MO 5-Ex-M

Explosion-proof electric multi-turn actuator MO 5-Ex-M

Type number: 167
Enclosure: IP 66
Trip torque: 300 to 1000 Nm
Rebuild speed: 15 to 100 min−1
Scope of work. of revolutions: 1.25 to 500
Weight: 93.5 to 103 kg
Ambient temperature: -50 to 60 °C
Connecting flange: F16
Work position: with the motor axis in a horizontal position (deviation +/-15°)
Type of protection: II 2G Ex db eb IIC T5/T4 Gb, II 2D Ex tb IIIC T135°C Db

Hi, my name Is Marko. I will be happy to help/advise you

Ing. Marko Čižmárik

Standard equipment

  • Supply voltage 3x400 V AC
  • Terminal board connection
  • Thermal protection of electromotor PTO (shut-off temperature 150°C)
  • 2 torque switches
  • 2 position switches
  • 2 additional position switches
  • Space heater with thermal switch
  • Mechanical connection ISO 5210, flange size F16, shape B3, D and non-standard shape C
  • Local position indicator
  • Torque switches blocking in limit positions
  • Manual control
  • Enclosure protection IP 66

Additional equipment 

  • Supply voltage 230 V AC, 220 V AC, 3x380 V AC, others - by agreement
  • Thermal protection of electromotor 3PTC (shut-off temperature 150°C)
  • Tandem switches
  • Position transmitter:
    • single/double potentiometer 1x100 Ω, 1x2000 Ω, 2x100 Ω, 2x2000 Ω
    • electronic position transmitter, passive/active, 2-wire/3-wire, 0/4 to 20 mA from R/I converter (with/without source)
    • CPT, DCPT 3M, passive/active, 2-wire/3-wire, 4 to 20 mA (capacitive transmitter with/without source)
  • Electrical local control unit
  • Gold coated contacts of microswitches
  • Mechanical connection:
    • ISO 5210, flange size F16, shape A
    • ГOCT P 55510, shape V
    • other non-standard
  • Enclosure rotection IP 67

Similar products

Category products

Explosion-proof electric multi-turn actuator UM 1-Ex-M

Type number: 136 Enclosure: IP 66, IP 68 Trip torque: 4 to 64 Nm Rebuild speed: 10 to 80 min−1 Scope of work. of revolutions: 3.125 to 160
Type number: 136 Enclosure: IP 66, IP 68 Trip torque: 4 to 64 Nm

Explosion-proof electric multi-turn actuator UM 2-Ex-M

Type number: 137 Enclosure: IP 66, IP 68 Trip torque: 18 to 100 Nm Rebuild speed: 10 to 40 min−1 Scope of work. of revolutions: 3.125 to 160
Type number: 137 Enclosure: IP 66, IP 68 Trip torque: 18 to 100 Nm

Explosion-proof electric multi-turn actuator MO 3-Ex-M

Type number: 100 Enclosure: IP 66 Trip torque: 26 to 150 Nm Rebuild speed: 16 to 95 min−1 Scope of work. of revolutions: 1 to 685
Type number: 100 Enclosure: IP 66 Trip torque: 26 to 150 Nm

Explosion-proof electric multi-turn actuator MO 4-Ex-M

Type number: 165 Enclosure: IP 66, IP 55 Trip torque: 95 to 500 Nm Rebuild speed: 16 to 180 min−1 Scope of work. of revolutions: 1.75 to 685
Type number: 165 Enclosure: IP 66, IP 55 Trip torque: 95 to 500 Nm

Explosion-proof electric multi-turn actuator MO 5-Ex-M

Type number: 167 Enclosure: IP 66 Trip torque: 300 to 1000 Nm Rebuild speed: 15 to 100 min−1 Scope of work. of revolutions: 1.25 to 500
Type number: 167 Enclosure: IP 66 Trip torque: 300 to 1000 Nm

An important fact of reliable operation is not only the correct design of fittings and servo drives, but also their subsequent care. With regular inspections and planned maintenance, you will prevent malfunctions and thus increase the reliability of the operation and extend its service life. For this purpose, the company REGADA also offers you comprehensive care of servo drives in your operation or just a selection from some of the listed services:

  1. Supervision during the first start-up of actuators in operation
  2. Connection and testing of actuators
  3. Connections and start-up of Rematic actuators - instruction
  4. Attaching the actuators to the valves and starting them
  5. Maintenance of actuators and periodic inspections
  6. Post-warranty repairs at the customer
  7. Post-warranty repair offer in Regada
  8. Training of service personnel
  9. Spare parts